-40%
Rampart (RCU-VBS) Control Panel
$ 212.18
- Description
- Size Guide
Description
Rampart (RCU-VBS) Control PanelDesigned for high security and vehicle barrier operations.
The Rampart RCU-VBS control system delivers advanced AES encrypted protection for both new and existing high security vehicle barrier installations. Rampart’s CeLAN bus provides secure 128-bit AES encrypted communication between all CeLAN devices connected to the system. Utilizing the CeLAN VBS (Vehicle Barrier System) Module, the system is capable of controlling and monitoring vehicle barrier systems, gate arms, traffic lights and rolling gates, swing gates and garage doors.
Features:
Eight general purpose inputs for security device monitoring
Supports up to 20 VBS barrier controllers
Pre-defined input configurations for standardization
Up to 252 definable user codes for system user login/logout option
Onboard 12VDC 5 Amp auxiliary power output
Dual CeLAN ports, supports up to 100 devices
6000 event buffer with time and date stamp
Field upgradeable software
CeLAN expansion – Communication Copper, Fiber Optics or TCP/IP
5.7” color touchscreen for high security vehicle barrier operation
All modules have built in tamper inputs for enclosure protection
Complete metrics tracking, event database, improves performance and reduces costs.
12 or 24 hour clock display
User and installer help menus
Auto daylights savings option
Dual redundant fiber configuration option
Microprocessor based vs. older style PLC control
Each input capable of reporting the following:
Open circuit
Short circuit
Ground fault
Print all system VBS events or selectable via programming
Real time system battery voltage and current readings
Supports up to 3 back-up batteries (54 Ahr) supervised and charged separately
Remote power supply option fully supervised AES Encrypted 5A @ 12VDC
Specifications:
Power Requirements:
24 VAC nominal (16.0 VAC minimum, 35 VAC maximum), Rated output current is only available at 24 VAC or above. Limited output current is available at 16.0 VAC minimum. Operating below 24 VAC Nominal is intended for short term emergency operation only.
Output Power:
10-14 VDC @ 5A Max, 2.5A Standby
Maximum battery charging (standby):
1.5 A
CINCH Stick Port:
One (1) - 128 Bit AES Encrypted, CINCH
Inputs:
Eight supervised, hardwired zones, 3.0 K ohm for security devices and enclosure tamper
Outputs:
Two, panel programmable outputs with "Form C" relay contacts (COMMON, N/C, N/O). Relay contacts rated 10A @ 24 VDC, 10A@24VAC, 10A@40VAC maximum.
Operating Temperature:
32° to 120° F (0° to 49° C), up to 140° F (60° C) under temporary conditions
Maximum Humidity:
90% relative humidity